2B Tech has taken the next step in miniaturization of UV-based ozone monitors by developing the Personal Ozone Monitor or "POM". The POM has dimensions of 4 x 3 x 1.5 inches and weighs only 0.75 lb (340 g). It has a built in GPS so that ozone measurements may be logged continuously along with geographic location. By folding the optical path in the shape of a "U", it was possible to achieve the same path length in the POM as in the Models 202, 205 and 106-L and thus have similar precision and accuracy (~2 ppb).
- Personal exposure monitoring for studies of health effects of air pollutants
- Health and safety monitoring at industrial sites using ozone
- Vertical profiling using balloons, kites, RPVs and light aircraft where space and weight are highly limited
- Long-term monitoring at remote locations where power is highly limited
- Urban arrays of ground-based detectors
Specifications
Measurement Principle | UV Absorption at 254 nm |
Linear Dynamic Range | 2.0 ppb to 10 ppm |
Resolution | 0.1 ppb |
Precision (1σ; rms noise) | Greater of 2.0 ppb or 2% of reading |
Accuracy | Greater of 2.0 ppb or 2% of reading |
Limit of Detection (2σ) | 4.0 ppb |
NIST-Traceable Calibration | Yes |
Measurement Interval | 10 s (Data averaging options: 10 s, 1 min, 5 min, 1 hr) |
Flow Rate (nominal) | ~0.8 Liter/min |
Flow Rate Requirement | >0.5 L/min |
Baseline Drift |
<2 ppb/day |
Sensitivity Drift |
<1%/day |
Measurement Time, Frequency | 10 s, 0.1 Hz |
Response Time, of Step Change | 20 s, 2 points |
Averaging Times | 10 s, 1 min, 5 min, 1 hr |
Data Storage | 8,192 lines (10 s avg ~1 day; 1 min avg ~1 wk; 5 min ~1 mo; 1 hr avg ~1 yr) |
Ozone Units | ppb, ppm, pphm, µg m-3, mg m-3 |
Pressure Units | mbar, torr |
Temperature Units | °C, K |
T and P Corrected | Yes |
Operating Temperature Range | 0 to 50 °C |
Power Requirement; Supplied by battery or 110/220 VAC Power Pack |
7-24 V dc, nominally 250 mA at 12 V, 3.0 watt |
External Battery | 7.4 Volt, 1.6 amp hour, Lithium Polymer Battery, 5-8 hr |
Size | 4.0 x 3.0 x 1.5 inches (10.2 x 7.6 x 3.8 cm) |
Weight | 0.75 lb (0.34 kg) |
Data Transfer Baud Rate | 19200 |
DewLine™ | Yes |
GPS | Yes |
System Includes
- POM™ Personal Ozone Monitor™
- AC Power Adapter (100-240 VAC to 12 VDC) with Country-Specific Plug
- Cigarette Lighter Adapter
- 7.4 V Lithium Polymer Battery
- Battery Charger
- Serial Port Cable
- USB Cable
- Zeroing Cartridge
- CD with Operation Manual, 2B Display Software and USB Driver
- Instrument Birth Certificate
- Calibration Data and NIST-Traceable Calibration Certificate
- One Year Warranty
Model Mini-Hicon高浓度臭氧分析仪应用
臭氧发生器出口的浓度测量
半导体元器件和芯片制造
水处理应用
超纯水系统
科学研究
医药、生物技术
Model Mini-Hicon高浓度臭氧分析仪主要规格
量程:0 到400 g/m3,0 到26 % w/w (其它量程可选)
单位:g/m3,g/Nm3和% w/w
重复性:0.5 g/m3 或1% 的读数, 包括零点漂移
(可提供更高精度)
分辨率:0.1 g/m3 ;0.01 % w/w
模拟输出:4-20mA
测量环境中的臭氧浓度,检测环境臭氧是否超标,臭氧浓度高于一定值时是有毒和腐蚀性气体。2000型臭氧分析仪是监测气体发生设备、气柜、气体输送系统 、半导体设备和卫生环境的臭氧浓度的理想选择。
2000型单点、多点臭氧分析仪主要特点:
●微机控制
●紫外吸收技术
●多可接入5个取样点
●内置现场编程,可编取样次序
●每通道4-20mA隔离输出
●每通道双报警
●高稳定光学系统
2000型单点、多点臭氧分析仪技术参数:
取样点数量 |
1,3或5个内置式多通道阀 |
量程 |
0-1ppm,0-10ppm,0-100ppm,0-1,000ppm等单一量程可选 |
分辨率 |
0.001ppm(0-1ppm或0-10ppm),0.01ppm(0-100ppm量程)和0.1ppm(0-1,000ppm量程) |
线性度 |
在全量程上优于99% |
零点漂移 |
单路无,数字自动归零;多路:0.005ppm每月 |
环境操作条件 |
5-45℃,0-95RH 非冷凝 |
E-UV-100多功能紫外臭氧分析仪:
E-UV-100 臭氧分析仪是全面测量空气中臭氧含量的仪器。量程0.01-900ppm(体积比),精确度2%,含有内置数据记录器供数据储存和下载。仪器体积小、重量只有2.1kg,12VDC的外部电源,适用于实验室研究、工艺监测、家电质量检验、室内空气质量调研、质量检验、温室大棚和高空气象调查等应用场合。输出数字显示、0-2.5VDC和4-20mA等,有RS232数据实时传输和USB接口,仪器可储存长达四天的读数,数据显示间隔10秒。仪器内置过滤器,LED提示更换。该仪器是工艺控制、家电、臭氧发生器检验和检验的理想工具。
E-UV-100 臭氧分析仪技术规格:
技术规格
UV 光源: 254 nm 水银灯
范围: 0.01-900 ppm v/v;3 挡量程,自动换挡:0-1.00 ppm,0-10.0 ppm,0-900.0 ppm
输出: 数字显示,0-2.5 V,4-20 mA,实时数据下载,不需其它软件
精度: 2%
采样间隔: 10 秒
LED 指示: On-off(开-关),Recalibrate(重新校准), Change Filter(更换过滤器),取样区浓度>0.1 ppm报警
尺寸: 89 mm X 178 mm X 203 mm
重量: 2.1 kg (4.7 lbs)
电源要求: 12 VDC @400 mA
保质期: 1年
The new Model 212 Scrubberless Ozone Monitor uses the proven ultraviolet (UV) absorption method with an innovative gas-phase scrubber technology to measure ozone virtually free from interferences. In the reference mode, the instrument uses the reaction between ozone and nitric oxide (NO) to selectively remove ozone from the sample. This reaction is orders of magnitude faster than with any other ambient gas, resulting in the removal of only ozone and not potentially interfering compounds that absorb UV light. The instrument is ideally suited for measurements of ozone in heavily polluted air where interference is likely from particulates, mercury, or VOCs. The ozone monitor combines the stability of our proven dual beam ozone monitors with our selective scrubber technology to provide accurate ozone measurements in the most polluted air.
The gas-phase scrubber technology uses NO to quantitatively react with ozone and remove it from the sample. This reaction has long been used as a gas phase titration for the measurement of either NO or O3. In the Scrubberless Ozone Monitor, a low concentration of NO is added to the sample to generate ozone-free, reference air. The light intensity is measured in the reference and sample modes, and the concentration of ozone is calculated directly from Beer's Law. Nitric oxide can be supplied from an external NO cylinder and will provide over a year of gas supply. Alternatively, nitric oxide can be generated inside the instrument using an optional photolytic NO generator and an external cylinder of nitrous oxide (N2O), which is non-toxic, non-corrosive and relatively inexpensive.
All 2B Tech ambient air monitors offer remote instrument operation via RS-232, choice of averaging time (2 s to 1 hr), analog output (0-2.5 V), current output (4-20 mA), internal data logger, and optional flash memory. Our data display and graphing software allows continuous display of data which can be saved for offline analysis
Features
- Virtually interference-free measurement of ambient ozone
- Free of signal quenching interferences inherent to chemiluminescence methods
- DewLine™ for elimination of water vapor interference, a unique feature of 2B Tech instruments
- Inexpensive, simple, and robust instrument design in a 19” rack mount enclosure
- Touchscreen display
- Internal data logger and USB flash memory
- Dual beam optical bench with high precision
- Stable calibration (calibration suggested annually)
- Electronic sample and nitric oxide flow control
- Internal long-life sample pump
- Under evaluation as a Federal Equivalent Method (FEM)
- Convenient user interface, including remote operation via RS-232 communication
- Optional internal NO generator using non-toxic, noncorrosive nitrous oxide (N2O)
Options
- GPS for continuous logging of latitude, longitude and altitude
- External particle filter
Specifications
Measurement Principle | UV Absorption at 254 nm; Dual Beam |
Linear Dynamic Range | 0.5 ppb to 2.0 ppm |
Resolution | 0.1 ppb |
Precision (1σ; rms noise) | Greater of 0.5 ppb or 1% of reading for 10-s average |
Accuracy | Greater of 1.0 ppb or 2% of reading |
Limit of Detection (2σ) | 1.0 ppb |
NIST-Traceable Calibration | Yes |
Flow Rate (nominal) | ~2 Liter/min |
Flow Rate Requirement | >1.2 L/min |
Baseline Drift |
<1 ppb/day |
Sensitivity Drift |
<0.5%/day |
Measurement Time, Frequency | 2 s, 0.5 Hz |
Response Time, of Step Change | 4 s for 2-s averaging; 20 s for 10-s averaging |
Averaging Times | 2 s, 10 s, 1 min, 5 min, 1 hr |
Internal Data Logger Capacity | 14,336 lines (10 s avg. = 1.4 days; 1 min avg = 10 days; 5 min avg = 1.4 mo; 1 hr avg = 1.6 yr); Virtually unlimited capacity with USB Flash Drive |
Ozone Units | ppb, ppm, pphm, µg m-3, mg m-3 |
Pressure Units | mbar, torr |
Temperature Units | °C, K |
T and P Corrected | Yes |
Operating Temperature Range | 10 to 50 °C |
Operating Altitude Range | ~0-30 km (~30-1000 mbar) |
Power Requirement; Supplied by Battery or 110/220 VAC Power Pack |
12 V dc or 120/240 V ac, 1.1 A at 12 V, 13 watt; 8 watt with Touch Screen off |
Size | Rackmount: 17" w x 14.5" d x 5.5" h (43 x 37 x 14 cm) |
Weight | 14.3 lb (6.5 kg) |
Analog Inputs for Internal Logging of Other Instruments | 3 Analog Inputs, 0-2.5 V; For example could log external T, P and RH |
Data Outputs | Touch Screen Display, USB, RS232, 0-2.5 V Analog, Optional 4-20 mA Analog |
Data Transfer Baud Rates | 1200, 2400, 4800, 19200 |
Output Ranges | User Defined Scaling Factor in Menu |
DewLine™ | Yes |
Long Life Pump | Yes, 20,000 hr |
Flow Meter | Yes |
Options | GPS, Lamp Heater; Bluetooth for wireless data transmission |
System Includes
- Model 211 Scrubberless Ozone Monitor
- AC Power Adapter (100-240 VAC to 12 VDC) with Country-Specific Plug
- Zeroing Cartridge
- Operation Manual on CD
- Calibration Data and NIST-Traceable Calibration Certificate
- Instrument Birth Certificate
- One Year Warranty
2B臭氧分析仪202型使用254nm紫外光吸收法,适用于监测大气中的臭氧浓度,量程由1.5ppbv至100ppmv。分析仪特点高精度、体积细小、重量(4.7磅, 2.1公升)及低电量消耗。备有遥控监测配件。
美国2B公司的205型双光束紫外光臭氧分析仪,采用的254nm紫外双光束光源技术及设计,可以同时测量被测样品臭氧值及去臭氧的净化空气值。结合其它技术设计,205型双光束紫外光臭氧分析仪的测量响应时间仅需2秒,成为市场上快响应时间的臭氧分析仪。仪器量程由1ppbv至100ppmv。该仪器具有高精度(1ppb)、体积小、重量轻(5磅, 2.3kg)及耗电量低。特别适合使用于航天及汽球上的大气臭氧测量。
Model 205双光束紫外臭氧分析仪产品应用:
- 气球及航空的大气测量
- 建立遥控监测网络
- 建立城市监测网络
- 个人及工作环境监测
- 工业生产中监测
Model 205双光束紫外臭氧分析仪产品特点:
- 使用双束254nm紫外光吸收法
- 高精度及分解度,量程由1ppbv至100ppmv
- 2秒响应时间,较同类型产品优越
- 低电量消耗,能以12V DC (5.0W)外置电源操作
- DewLineTM 技术减低水气对仪器的干扰
- 内置数据记录功能及实时时钟显示。并有3组仿真讯号输出
- 以RS-232输出时间、日期、臭氧浓度、仪器内温度、气压及另外3组补充轮入讯号,例如外置温度、湿度及气压
- 模拟输出0-2.5V
- 选配GPS功能及CF记忆卡
205双光束臭氧分析仪同时测量Io (臭氧被净化的空气) 和I (臭氧没有净化的空气) 电流值。使得臭氧测量的时间间隔达到2秒,成为市场上基于紫外法的快的臭氧分析仪,测量环境中的臭氧浓度可达100ppm,同时保留了体积小、重量轻和功耗低的特点。快速测量对于飞行器和气球测量(臭氧)的场合是特别想要的,在那里,高空解决方法很重要。做为选择,用户可以选择内部多个点的平均值以得到更好的精度。
选件:
1:硬质保护携带箱;
2:长寿命蓄电池,可用于野外或者没有市电时的长时间供电
附:Model 202 臭氧分析仪
单光路的Model 202臭氧分析仪,美国EPA已经指定使用方法第“901-O3 Model 202”,用于Model 202上。包含国家森林服务网络,使用202用于其数据库。
Model 205双光束紫外臭氧分析仪技术规格:
测量原理:254 nm紫外吸收法
可分析量程:1 ppbv 到100 ppmv
精度和准确度:优于1 ppbv或2%
测量间隔:2秒(平均选项:2秒,10秒,1分钟,5分钟和1小时)
流量:~1 L/min
数据储存:20,480行数据(10秒 平均= 2.4天,5分 平均= 2.4月)
数据输出:RS-232,0-2.5V模拟量,LCD显示
电源要求:12 V DC,5.0 W (2.9 W低功耗模式下)或120/240 VAC
尺寸:9 cm x 21 cm x 29 cm
重量:2.3 kg;0.9 kg(不含箱子)
Model 202紫外臭氧分析仪产品介绍:
Model 202紫外臭氧分析仪应用:
●气球及航空的大气测量
●建立城市监测网络
●个人及工作环境监测
●工业生产中监测
Model 202紫外臭氧分析仪特点:
●使用254nm紫外光吸收法
●高精度及分解度,量程由1.5ppbv至100ppmv
●低电量消耗,能以12V DC (5.0W)外置电源操作
●DewLine技术减低水气对仪器的干扰
●模拟输出0-2.5V
本臭氧分析仪重量轻,只有1.9kg,相对于传统的仪器它的功耗低(大约3.6w),因而很适合于在下列场所使用,例如:
1:在偏僻的地方进行长期监测,那里电力受到高度限制;
2:城市地面基站探测;
3:为研究空气污染对健康影响而做的个人暴露监测;
量程:1.5 ppbv到100 ppmv,0-1,1-10,10-100ppm 自动换挡,ppb单位显示
精度和准确度:优于1.5 ppbv 或2%
测量间隙:10 秒(平均选项:10s,1 min,5 min,1 hr)
流量率:约1 l/min
数据储存:20480行(每10s 储存一个数据平均可达到2.4天,每5分钟可达2.4 月)
数据输出:RS-232,0~2.5V DC 模拟,LCD显示
数据输入:3 通道,0~2.5 V DC
电源:12 V DC,4.0 W (2.9 W 低功耗模式下)
Model 202紫外臭氧分析仪其它特征:
车载电源适配器可用于运动中/野外大气化学研究。可输入三个模拟信号用于科学研究。
有温度、湿度和海拔高度修正(海拔升高1000米产生的误差高达14%!),随时随地确保读数精确;Dew-Line湿度修正技术克服了传统紫外臭氧分析仪的限制,使得湿度对臭氧测量的干扰从高达近百个ppb降低到可以接受的几个ppb的水平。
Model 202紫外臭氧分析仪技术规格:
操作原理 | 紫外光254nm灯 |
量程 | 1.5ppbv-100ppmv |
精度 | ±2% |
采样时间 | 10秒、1分钟、5分钟及1小时 |
记忆容量 | 20,480组 |
输出 | 数码显示,0-2.5V,RS-232 |
流量 | 大约1L/min |
尺寸 / 重量 | 90 × 210 × 290 mm / 4.7lb |
电源 | 12VDC交流电 |
Model 202紫外臭氧分析仪可选配置:
1:12VDC可充电移动电源:野外使用,供电时间长达12小时,保证使用8小时;如需更长时间的电源,请咨询。
2:闪存卡:本仪器可以储存数月的数据,然而现场客户更希望用闪存卡快速、可靠、简单地传输数据。使用本公司提供的64M卡,可储存138天按10秒一次的数据(臭氧,内部温度,内部压力,日期,时间和三个外部输入数据如外部温度、外部压力和湿度);使用1GB的卡则可储存长达6年的数据。
3:备用泵方案:本仪器配置的泵的连续使用寿命为5,000小时,如安装在遥远的地区连续运转则建议使用“备用泵方案”。本方案中,两个泵安装在一起,外加一个微型流量计。流量受到连续监测,当流量低于某一限定值时,微处理器关闭主泵而启动备用泵。显示器上出现*提示泵需要更换。本方案减少因泵失效而导致丢失数据和停止工作的风险。
4:GPS卫星定位系统:连续记录仪器的地理位置。
5:颗粒物过滤器:提供外部过滤器以防污染仪器。提供PVDF (Kynar®) 过滤器盒和PTFE (Teflon®) 过滤器,每盒10个。
6:其它现场使用建议备件。
A-21ZX袖珍型臭氧检测仪:
A-21ZX袖珍型臭氧检测仪用于臭氧发生器、阀门、管道和普通环境的臭氧泄漏检测及评估。当室内臭氧平均浓度低于0.1ppm时,A-21ZX可作为的监测器使用。在适宜的温度条件下,它也可用于室外的臭氧研究。
特点:
采用热金属氧化物半导体传感器,灵敏度高
体积小,重量轻
“即开即用”(Instant ON)特征
操作简单,易于校准和维护
数字显示,分辨率0.01ppm
内置式充电电池可连续工作8小时以上
传感器 热金属氧化物半导体传感器(HMOS) 测量范围 0-10ppm,长期监测0-0.1ppm 灵敏度 0.02ppm 准确度 20% 响应时间 <10秒 工作环境 0-40℃,0-80%RH 工作电源 12VDC/200mA,内“+”外“-” 电池寿命 充满电后可工作8小时以上 尺寸 50×100×25(mm) 重量 170g
技术参数 |
Model 106紫外臭氧分析仪简介:
美国2B Technologies公司的臭氧分析仪106型使用及稳定的臭氧测量技术:254nm紫外光吸收法(符合国家臭氧测量标准),测量大气臭氧范围从1.5ppb到100ppm,分析仪具有高精度及分辨率、体积细小、重量只有4.7磅, 2.1kg及低电量消耗,适合于户外操作。2B公司另有升级型,型号202不单单保持254nm紫外光吸收法、高精度及分辨率等优点,更具备额外功能,如USB接口、4-20mA模拟讯号输出、继电器组设置值、警报灯。
Model 106紫外臭氧分析仪产品特点:
●以紫外光吸收法测量,可靠稳定
●高准确度(1.5 ppb),分析量程(1.5 ppbv 到100 ppmv)
●低电池消耗,12 V DC(4.0 W),可以使用外置电池组或AC充电器
●体积细少,轻巧,便携式
●内置数据记录器,数据通过实时时钟记录下来。
●平均值选项:10 s, 1 m, 5 m and 1 hr
●通过USB及RS-232 输出时间/日期、臭氧值、 内置温度及气压
●通过模拟讯号(0-2.5 V及4-20 mA)输出臭氧值,能连接其它控制装置
Model 106紫外臭氧分析仪产品应用:
●建立遥控监测网络
●室内臭气监测
●建立城市监测网络
●个人及工作环境监测
●工业生产中需要高精度及分辨率的臭氧监测
Model 106紫外臭氧分析仪产品规格:
OEM-106-L 量程0-100 ppm 分辨率0.0001 ppm (0.1 ppb) 精准度高于2 ppb或2%读值
OEM-106-M 量程0-1000 ppm 分辨率0.01 ppm 精准度高于0.01 ppm或2%读值
OEM-106-H 量程0-20 wt% 分辨率0.01 wt% 精准度高于0.01 wt% 或2% 读值
测量原理 | 254nm紫外光吸收法 |
水汽管理 | DewLine(Nafiono 软管) |
测量量程 | 1.5 ppbv 到 100 ppmv |
准确度及精度 | 大于1.5 ppb 或 测量的2% |
采样间隔 | 10 秒(平均值选项:10 s, 1 min, 5 min, 1 hr) |
流量 | 约1 公升/分钟 |
数据储存 | 12,288(10s 平均 = 1.4日,1分钟平均 = 8.5日, 5分钟平均 = 42日, 1小时 = 1.4 年) |
数据输出 | USB; RS-232; 0-2.5 V; 4-20 mA |
模拟讯号输出量程 | 0-1 ppm; 0-10 ppm; 0-100 ppm; 或客户要求 |
臭氧单位 | ppb, ppm, pphm, mg/m3, mg/m3 |
继电器组设定值 | 值及值的设定值范围:0.000 到 100.000 ppm |
电源 | 12 V DC or 120/240 V AC;350 mA;4.2W |
警报灯 | 仪器启动;臭氧浓度大于100 ppb;校准日期;过滤器需要更换 |
尺寸 | 9.5 x 21.0 x 21.6 cm (3.75 x 8.25 x 8.50 in) |
重量 |
2.1 kg (4.7 lb) |